Section 310. Plans and specifications  


Latest version.
  • The plans and specifications for a proposed impounding structure required in 4VAC50-20-70 for construction activities and in 4VAC50-20-80 for alteration activities shall consist of a detailed engineering design report (Design Report for the Construction or Alteration of Virginia Regulated Impounding Structures) and engineering drawings and specifications, with the following as a minimum:

    1. The name of the project; the name of the owner; classification of the impounding structure as set forth in this chapter; designated access to the project and the location with respect to highways, roads, streams and existing impounding structures and impoundments that would affect or be affected by the proposed impounding structure.

    2. Cross-sections, plans, profiles, logs of test borings, laboratory and in situ test data, drawings of principal and emergency spillways, impounding structures, outlet works, drain system and appurtenances, and other project components in sufficient detail to indicate clearly the extent and complexity of the work to be performed.

    3. Contract drawings should include, but not be limited to, foundation and abutment treatment, stream or river diversion, excavation and material fill processes, phased fill and compaction and drainage devices.

    4. The erosion and sediment control plan, as approved by the local government, which minimizes soil erosion and sedimentation during all phases of construction or alteration.

    5. Technical specifications, as may be required to describe the materials, performance, and methods of the construction and construction quality control for the project.

Historical Notes

Derived from VR625-01-00 § 5.8, eff. February 1, 1989; amended, Volume 24, Issue 25, eff. September 26, 2008.

Statutory Authority