A. No owner or other person shall cause or permit any material to be produced, handled, stockpiled or transported without taking measures to reduce to a minimum any particulate matter from becoming airborne. Where it is practical to measure the emission, the emission shall not exceed the limits established by Table 4-14. All such airborne particulate matter emanating from the yards, sidings or roads of such operations shall be considered fugitive dust and shall be controlled as stipulated in 9VAC5-40-1860. All crushers shall be fitted with liquid sprays or other appropriate systems which effectively limit the escape of airborne dust. Vibrating and shaker screens handling dry materials shall be enclosed or fitted with a collector system which will prevent the release of more than 0.05 grains per standard cubic foot. All feeders, elevators, conveyors, transfer points, discharge points and loading points shall be equipped with collectors, sprays or other means when necessary to minimize the escape of dust.
TABLE 4-14
Process Weight
Maximum Allowable Emission Rate
Lb/Hr
Tons/Hr
Lb/Hr
100 or less
0.05 or less
0.551
200
0.10
0.877
400
0.20
1.40
600
0.30
1.83
800
0.40
2.22
1000
0.50
2.58
1500
0.75
3.38
2000
1.00
4.10
2500
1.25
4.76
3000
1.50
5.38
3500
1.75
5.96
4000
2.00
6.52
5000
2.50
7.58
6000
3.00
8.56
7000
3.50
9.49
8000
4.00
10.4
9000
4.50
11.2
10000
5.00
12.0
12000
6.00
13.6
16000
8.00
16.5
18000
9.00
17.9
20000
10.00
19.2
30000
15.00
25.2
40000
20.00
30.5
50000
25.00
35.4
60000
30.00
40.0
70000
35.00
41.3
80000
40.00
42.5
90000
50.00
44.6
120000
60.00
46.3
140000
70.00
47.8
160000
80.00
49.1
200000
100.00
51.3
1000000
500.00
69.0
2000000
1000.00
77.6
6000000
3000.00
92.7
B. Interpretation of emission standard in subsection A of this section shall be in accordance with 9VAC5-40-22.
C. The provisions of this section shall not apply to affected facilities identified in subsection A of this section and located in AQCR 7; however, the provisions of 9VAC5-40-270 shall apply to the facilities.