Section 970. User verification  


Latest version.
  • A. To verify that the medical waste treatment unit is functioning properly and that performance standards are achieved, the petitioner shall:

    1. Demonstrate that required resistant bacterial endospores are inactivated to criteria as specified in 9VAC20-120-910 B under standard operating procedures using protocols that have previously been approved by the department as specified under 9VAC20-120-950 and 9VAC20-120-960;

    2. Establish a frequency of biological monitoring; and

    3. Document and record all biological indicator and parametric monitoring data.

    B. To document treatment efficacy for steam sterilizers and autoclaves, the equipment operator shall:

    1. Adopt standard written operating procedures that denote:

    a. Sterilization cycle time, temperature, pressure

    b. Types of waste acceptable

    c. Types of containers and closures acceptable

    d. Loading patterns or quantity limitations;

    2. Document times/temperatures for each complete sterilization cycle;

    3. Use time-temperature sensitive indicators to visually denote the waste has been decontaminated;

    4. Use biological indicators placed in the waste load (or simulated load) periodically to verify conditions meet microbial inactivation requirements as specified in 9VAC20-120-910 B; and

    5. Maintain all records of procedure documentation, time-temperature profiles, and biological indicator results.