Section 730. General requirements for gathering pipelines  


Latest version.
  • A. Gathering pipelines shall be installed to be compatible with other uses of the area.

    B. No permit shall be issued for a gathering pipeline to be installed closer than 100 feet from any inhabited building or railway, unless site conditions as approved by the director warrant the use of a lesser distance and there exists a lease or agreement between the operator and the owner of the inhabited building or railway. A copy of the lease or agreement shall accompany the application for a permit.

    C. Materials used in gathering pipelines shall be able to withstand anticipated conditions. At a minimum this shall include:

    1. All plastic gathering pipeline connections shall be fused, not coupled.

    2. All buried gathering pipelines shall be detectable by magnetic or other remote means from the surface.

    D. All new gathering pipelines shall be tested to maintain a minimum of 110% of anticipated pressure prior to being placed into service.

    E. All gathering pipelines shall be maintained in good operating condition at all times.

Historical Notes

Derived from VR480-05-22.1 § 5.2, eff. September 25, 1991; amended, Volume 15, Issue 02, eff. November 11, 1998; Volume 29, Issue 03, eff. November 8, 2012; Volume 30, Issue 01, eff. October 10, 2013.

Statutory Authority

§§ 45.1-161.3 and 45.1-361.27 of the Code of Virginia.