Virginia Administrative Code (Last Updated: January 10, 2017) |
Title 13. Housing |
Agency 5. Department of Housing and Community Development |
Chapter 63. Virginia Uniform Statewide Building Code |
Appendix 9999. DOCUMENTS INCORPORATED BY REFERENCE (13VAC5-63)
-
International Code Council, Inc., 500 New Jersey Avenue, NW, 6th Floor, Washington, DC 20001-2070 (http://www.iccsafe.org/):
International Building Code - 2012 Edition
International Energy Conservation Code - 2012 Edition
International Existing Building Code - 2012 Edition
International Fire Code - 2012 Edition
International Fuel Gas Code - 2012 Edition
International Mechanical Code - 2012 Edition
International Property Maintenance Code - 2012 Edition
International Plumbing Code - 2012 Edition
International Residential Code for One- and Two-Family Dwellings - 2012 Edition
International Swimming Pool and Spa Code - 2012 Edition
ICC/ANSI A117.1-09, Accessible and Usable Buildings and Facilities, Approved November 26, 2003
Air Conditioning Contractors of America, 2800 Shirlington Road, Suite 300, Arlington, VA 22206 (https://www.acca.org/):
Manual J-11, Residential Load Calculation, Eighth Edition
Manual S-04, Residential Equipment Selection
ACI 318-11, Building Code Requirements for Structural Concrete, American Concrete Institute, 38800 Country Club Drive, Farmington Hills, MI 48331 (http://www.concrete.org/)
American Petroleum Institute, 1220 L Street, NW, Washington, DC 20005-4070 (http://www.api.org/):
API 650-09, Welded Tanks for Oil Storage, Eleventh Edition, June 2007 (Addendum 1, November 2008, Addendum 2, November 2009, effective May 1, 2010)
API 653-09, Tank Inspection, Repair, Alteration, and Reconstruction
ASHRAE 193-2010, Method of Test for Determining the Airtightness of HVAC Equipment, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, NE, Atlanta, GA 30329-2305 (https://www.ashrae.org/)
American Society of Testing Materials International, 100 Barr Harbor Drive, P.O. Box C700, West Conshocken, PA 19428-2959 (http://www.astm.org/):
ASTM C199-84(2005), Standard Test Method for Pier Test for Refractory Mortar
ASTM C315-07, Standard Specification for Clay Flue Liners and Chimney Pots
ASTM C1261-07, Standard Specification for Firebox Brick for Residential Fireplaces
ASTM D1557-07, Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3(2700 kN-m/m3))
ASTM E90-90, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions
ASTM E283-04, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
ASTM E329-02, Standard Specification for Agencies Engaged in the Testing and/or Inspection of Materials Used in Construction
ASTM F2006-10, Standard Safety Specification for Window Fall Prevention Devices for Nonemergency Escape (Egress) and Rescue (Ingress) Windows
ASTM F2090-08, Standard Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms
CAN/CSA-B64.10-01, Manual for the Selection and Installation of Backflow Prevention Devices/Manual for the Maintenance and Field Testing of Backflow Prevention Devices, June 2003, National Standards of Canada, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W5N6 (http://www.csa.ca)
American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990 (https://www.asme.org/):
ASME A17.1/CSA B44-2007 Safety Code for Elevators and Escalators
ASME A17.1/CSA B44-2010, Safety Code for Elevators and Escalators
ASME A18.1-2011, Safety Standard for Platform Lifts and Stairway Chairlifts
American Society of Sanitary Engineering, 901 Canterbury Road, Suite A, Westlake, OH 44145 (http://www.asse-plumbing.org/):
ASSE 1010-2004, Performance Requirements for Water Hammer Arrestors
ASSE 1022-03, Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment
ASSE 1024-04, Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets)
ASSE 5010-1013-1, Field Test Procedure for a Reduced Pressure Principle Assembly Using a Differential Pressure Gauge, 1991
ASSE 5010-1015-1, Field Test Procedure for a Double Check Valve Assembly Using a Duplex Gauge, 1991
ASSE 5010-1015-2, Field Test Procedure for a Double Check Valve Assembly Using a Differential Pressure Gauge - High- and Low-Pressure Hose Method, 1991
ASSE 5010-1015-3, Field Test Procedure for a Double Check Valve Assembly Using a Differential Pressure Gauge - High Pressure Hose Method, 1991
ASSE 5010-1015-4, Field Test Procedure for a Double Check Valve Assembly Using a Site Tube, 1991
ASSE 5010-1020-1, Field Test Procedures for a Pressure Vacuum Breaker Assembly, 1991
ASSE 5010-1047-1, Field Test Procedure for a Reduced Pressure Detector Assembly Using a Differential Pressure Gauge, 1991
ASSE 5010-1048-1, Field Test Procedure for a Double Check Detector Assembly Using a Duplex Gauge, 1991
ASSE 5010-1048-2, Field Test Procedure for a Double Check Detector Assembly Using a Differential Pressure Gauge - High- and Low-Pressure Hose Method, 1991
ASSE 5010-1048-3, Field Test Procedure for a Double Check Detector Assembly Using a Differential Pressure Gauge - High-Pressure Hose Method, 1991
ASSE 5010-1048-4, Field Test Procedure for a Double Check Detector Assembly Using a Site Tube, 1991
ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers/Structural Engineering Institute, 1801 Alexander Bell Drive, Reston, VA 20191-4400 (http://www.asce.org/sei/)
National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471 (http://www.nfpa.org/):
NFPA 13-10, Installation of Sprinkler Systems
NFPA 13R-10, Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height
NFPA 13D-10, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes
NFPA 70-11, National Electrical Code
NFPA 72-10, National Fire Alarm Code
NFPA 105-10, Standard for the Installation of Smoke Door Assemblies
NFPA 285-06, Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components
NFPA 495-01, Explosive Materials Code
NFPA 701-10, Standard Methods of Fire Tests for Flame-propagation of Textiles and Films
NFPA 704-12, Standard System for the Identification of the Hazards of Materials for Emergency Response
NFPA 720-09, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment
NSF 50-2009a, Equipment for Swimming Pools, Spas, Hot Tubs and Other Recreational Water Facilities, NSF International, 789 Dixboro Road, P.O. Box 130140, Ann Arbor, MI 48113 (http://nsf.org)
TFI RMIP-09, Aboveground Storage Tanks Containing Liquid Fertilizer, Recommended Mechanical Integrity Practices, December 2009, The Fertilizer Institute, 820 First Street, NE, Suite 430, Washington, DC 20002
Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062 (http://www.ul.com):
UL 87A-12, Outline of Investigation for Power-Operated Dispensing Devices for Gasoline and Gasoline/ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent
UL 294-2010, Access Control System Units (Fifth Edition-with revisions through September 17, 2010)
UL 1784-01, Air Leakage Tests of Door Assemblies, revised July 2009
UL 2034-2008, Standard for Single and Multiple Station Carbon Monoxide Alarms, revised February 2009
UL 2075-2013, Gas and Vapor Detectors and Sensors (Second Edition, March 5, 2013)