Section 520. Chapter 3 General requirements  


Latest version.
  • A. Delete Section 302.1 of the IPMC.

    B. Change Section 302.2 of the IPMC to read:

    302.2 Grading and drainage. All premises shall be graded and maintained to protect the foundation walls or slab of the structure from the accumulation and drainage of surface or stagnant water in accordance with the VCC.

    C. Change Section 302.3 of the IPMC to read:

    302.3 Sidewalks and driveways. All sidewalks, walkways, stairs, driveways, parking spaces and similar spaces regulated under the VCC shall be kept in a proper state of repair, and maintained free from hazardous conditions. Stairs shall comply with the requirements of Sections 305 and 702.

    D. Delete Section 302.4 of the IPMC.

    E. Change Section 302.5 of the IPMC to read:

    302.5 Rodent harborage. All structures and adjacent premises shall be kept free from rodent harborage and infestation where such harborage or infestation adversely affects the structures.

    F. Delete Sections 302.8 and 302.9 of the IPMC.

    G. Delete Section 304.1.1 of the IPMC.

    H. Change Section 304.7 of the IPMC to read:

    304.7 Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall be discharged in a manner to protect the foundation or slab of buildings and structures from the accumulation of roof drainage.

    I. Change Section 304.14 of the IPMC to read:

    304.14 Insect screens. During the period from April 1 to December 1, every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored, shall be supplied with approved tightly fitting screens of not less than 16 mesh per inch (16 mesh per 25 mm) and every screen door used for insect control shall have a self-closing device in good working condition.

    Exception: Screens shall not be required where other approved means, such as mechanical ventilation, air curtains or insect repellant fans, are used.

    J. Delete Sections 304.18, 304.18.1, 304.18.2 and 304.18.3 of the IPMC.

    K. Delete Section 305.1.1 of the IPMC.

    L. Add Section 305.7 to the IPMC to read:

    305.7 Carbon monoxide alarms. Carbon monoxide alarms shall be maintained as approved.

    M. Delete Section 306 of the IPMC in its entirety.

    N. Change Section 308.1 of the IPMC to read as follows and delete the remaining provisions of Section 308:

    308.1 Accumulation of rubbish and garbage. The interior of every structure shall be free from excessive accumulation of rubbish or garbage.

    O. Change Section 309.1 of the IPMC to read:

    309.1 Infestation. This section shall apply to the extent that insect and rodent infestation adversely affects a structure. All structures shall be kept free from insect and rodent infestation. All structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After extermination, proper precautions shall be taken to prevent reinfestation.

    P. Add IPMC Section 310 Lead-Based Paint.

    Q. Add Section 310.1 to the IPMC to read:

    310.1 General. Interior and exterior painted surfaces of dwellings and child care facilities, including fences and outbuildings, that contain lead levels equal to or greater than 1.0 milligram per square centimeter or in excess of 0.50% lead by weight shall be maintained in a condition free from peeling, chipping and flaking paint or removed or covered in an approved manner. Any surface to be covered shall first be identified by an approved warning as to the lead content of such surface.

    R. Add IPMC Section 311 Aboveground Liquid Fertilizer Storage Tanks (ALFSTs).

    S. Add Section 311.1 to the IPMC to read:

    311.1 General. ALFSTs shall be maintained in accordance with the requirements of Section 1701.16 of the VRC and the requirements of the VCC applicable to such ALFSTs when newly constructed and the requirements of the VRC when undergoing a change of occupancy to an ALFST and when repaired, altered or reconstructed, including the requirements for inspections and for a secondary containment system.