Section 434. Chapter 8 Alterations -- Level 2
-
A. Change Exception 2 of Section 805.2 to read:
2. Means of egress conforming to the requirements of the building code under which the building was constructed shall be considered compliant means of egress.
B. Change Item 7 of Section 805.3.1.1 of the IEBC to read:
7. In Groups R-2, H-4, H-5 and I occupancies and in rooming houses and childcare centers, a single exit is permitted in a one-story building with a maximum occupant load of 10 and the exit access travel distance does not exceed 75 feet (22 860 mm). In dwelling units within Group R-2 buildings, an occupant load of 12 shall be permitted to be substituted for the occupant load established above and, in addition, staff of such family day homes shall not be counted for the purposes of establishing occupant loads.