Section 110. Structural requirements for service buildings
-
A. All portions of the structure shall be properly protected from damage by ordinary use and by decay and corrosion. Exterior portions shall be of such material and be so constructed and protected as to prevent entrance or penetration of moisture and weather.
B. Effective ventilation of all service buildings shall be provided to prevent condensation, moisture and odors.
C. Interior of service buildings shall be finished in a light color and provided with adequate natural or artificial illumination, or both.
D. The floors of toilet and shower rooms shall be sloped to a properly trapped floor drain connected to the sewerage system.
E. Partitions between flush toilets in the same room shall be raised a minimum of eight inches from the floor to permit easy cleaning.
F. The interior finish of such buildings shall be of moisture resistant and easily cleanable material which will withstand frequent washing and cleaning. Special attention shall be given wall finishes immediately around lavatories, urinals, commodes and in showers to insure a surface in these heavily used areas which will withstand commercial use.
G. The floors shall be constructed of material impervious to water and be of easily cleanable material. Duck boards or walk ways made of wood or other absorptive material shall not be permitted.
H. All windows and openings to the outside from areas containing commodes and urinals shall be provided with fly-proof screening material of at least 16 mesh per inch.
I. Water closets and bathing facilities shall not be located in the same compartment.
J. Permanent service buildings shall be provided with an artificial light at the entrance to the building to facilitate its use at night: Provided, that primitive camps with privies may be exempted from this requirement.
K. Service buildings shall have appropriate signs to denote its use such as "Men's Toilet," "Women's Toilet," "Showers," etc.
L. Showers shall be equipped with a drain or drains which will prevent the shower water from running across floors that are used for other purposes.
M. All fixtures shall be of durable material which will be capable of withstanding the heavy usage which public facilities receive.