Section 1700. Manual and mechanical warewashing equipment, chemical sanitization - temperature, pH, concentration, and hardness  


Latest version.
  • A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subdivision 3 of 12VAC5-421-1900 shall be listed in 40 CFR 180.940, shall be used in accordance with the EPA-registered label use instructions,P and shall be used as follows:

    1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart:P

    Minimum
    Concentration

    Minimum
    Temperature

    mg/L (ppm)

    pH 10 or less
    °F (°C)

    pH 8 or less
    °F (°C)

    25-49

    120 (49)

    120 (49)

    50-99

    100 (38)

    75 (24)

    100

    55 (13)

    55 (13)

    2. An iodine solution shall have a:

    a. Minimum temperature of 68°F (20°C);P

    b. pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective;P and

    c. Concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm);P

    3. A quaternary ammonium compound solution shall:

    a. Have a minimum temperature of 75°F (24°C);P

    b. Have a concentration as specified under 40 CFR 180.940 and as indicated by the manufacturer's use directions included in the labeling;P and

    c. Be used only in water with 500 mg/L hardness or less or in water having a hardness no greater than specified by the manufacturer's label;P

    4. If another solution of a chemical specified under subdivisions 1, 2 and 3 of this section is used, the permit holder shall demonstrate to the regulatory authority that the solution achieves sanitization and the use of the solution shall be approved;P

    5. If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions;P and

    6. If a chemical sanitizer is generated by a device located on site at the food establishment it shall be used as specified in subdivisions 1 through 4 of this section and shall be produced by a device that:

    a. Complies with regulation as specified in §§ 2(q)(1) and 12 of the Federal Insecticide, Fungicide and Rodenticide Act (FIFRA),P

    b. Complies with 40 CFR 152.500 and 40 CFR 156.10,P

    c. Displays the EPA device manufacturing facility registration number on the device,Pf and

    d. Is operated and maintained in accordance with manufacturer's instructions.Pf

Historical Notes

Derived from Volume 18, Issue 10, eff. March 1, 2002; amended, Virginia Register Volume 24, Issue 02, eff. October 16, 2007; Volume 32, Issue 22, eff. July 12, 2016.

Statutory Authority

§§ 35.1-11 and 35.1-14 of the Code of Virginia.