Section 1560. Fixed equipment, elevation or sealing  


Latest version.
  • A. Except as specified in subsections B and C of this section, floor-mounted equipment that is not easily movable shall be sealed to the floor or elevated on legs that provide at least a 6 inch (15 centimeter) clearance between the floor and the equipment.

    B. If no part of the floor under the floor-mounted equipment is more than 6 inches (15 centimeters) from the point of cleaning access, the clearance space may be only 4 inches (10 centimeters).

    C. This section does not apply to display shelving units, display refrigeration units, and display freezer units located in the consumer shopping areas of a retail food store, if the floor under the units is maintained clean.

    D. Except as specified in subsection E of this section, counter-mounted equipment that is not easily movable shall be elevated on legs that provide at least a 4-inch (10 centimeter) clearance between the table and the equipment.

    E. The clearance space between the table and counter-mounted equipment may be:

    1. Three inches (7.5 centimeters) if the horizontal distance of the table top under the equipment is no more than 20 inches (50 centimeters) from the point of access for cleaning; or

    2. Two inches (5 centimeters) if the horizontal distance of the table top under the equipment is no more than 3 inches (7.5 centimeters) from the point of access for cleaning.

Historical Notes

Derived from Volume 18, Issue 10, eff. March 1, 2002; amended, Virginia Register Volume 26, Issue 07, eff. January 1, 2010.

Statutory Authority

§§ 35.1-11 and 35.1-14 of the Code of Virginia.